Current through Register Vol. 50, No. 11, November 20, 2024
Section XIII-1325 - Repair or Removal of Defects [49 CFR 192.245]A. Each weld that is unacceptable under §1321. C must be removed or repaired. Except for welds on an offshore pipeline being installed from a pipeline vessel, a weld must be removed if it has a crack that is more than 8 percent of the weld length. [ 49 CFR 192.245(a)]B. Each weld that is repaired must have the defect removed down to sound metal and the segment to be repaired must be preheated if conditions exist which would adversely affect the quality of the weld repair. After repair, the segment of the weld that was repaired must be inspected to ensure its acceptability. [ 49 CFR 192.245(b)]C. Repair of a crack, or of any defect in a previously repaired area must be in accordance with written weld repair procedures that have been qualified under §1305 Repair procedures must provide that the minimum mechanical properties specified for the welding procedure used to make the original weld are met upon completion of the final weld repair. [ 49 CFR 192.245(c)]La. Admin. Code tit. 43, § XIII-1325
Promulgated by the Department of Natural Resources, Office of Conservation, LR 9:230 (April 1983), amended LR 10:522 (July 1984), LR 30:1242 (June 2004).AUTHORITY NOTE: Promulgated in accordance with R.S. 30:501 et seq.