Section XI-4911 - Maximum Operating Pressures (Formerly section 1911)A. Except for surge pressures and other variations from normal operations, no operator may operate a pipeline at a pressure that exceeds any of the following: 1. the internal design pressure of the pipe determined in accordance with §4309;2. the design pressure of any other component of the pipeline;3. 80 percent of the test pressure for any part of the pipeline which has been hydrostatically tested under §4701-4711 of this regulation;4. 80 percent of the factory test pressure or of the prototype test pressure for any individually installed component which is excepted from testing under §4705B. No operator may permit the pressure in a pipeline during surges or other variations from normal operations to exceed 110 percent of the operating pressure limit established under Subsection A of this Section. Each operator must provide adequate controls and protective equipment to control the pressure within this limit.La. Admin. Code tit. 43, § XI-4911
Promulgated by the Department of Natural Resources, Office of Conservation, LR 12:115 (February 1986), repromulgated LR 49319 (2/1/2023).AUTHORITY NOTE: Promulgated in accordance with R.S. 30:4(C)(17) and R.S. 30:1104(A).