La. Admin. Code tit. 43 § XI-1309

Current through Register Vol. 50, No. 11, November 20, 2024
Section XI-1309 - Internal Design Pressure
A. Internal design pressure for the pipe in a pipeline is determined in accordance with the following formula.

P = (2 St/D) x E x F

P = internal design pressure in pounds per square inch gauge

S = yield strength in pounds per square inch determined in accordance with Subsection B of this Section

t = nominal wall thickness of the pipe in inches

D = nominal outside diameter of the pipe in inches

E = seam joint factor determined in accordance with Subsection E of this Section

F = a design factor of 0.72, except that a design factor of 0.60 is used for pipe, including risers, on a platform located offshore or on a platform in inland navigable waters, and 0.54 is used for pipe that has been subjected to cold working to meet the specified minimum yield strength and is subsequently heated, other than by welding or stress relieving as a part of welding to a temperature higher than 900° F (482° C) for any period of time or over 600° F (318° C) for more than one hour.

B. The yield strength to be used in determining internal design pressure under Subsection A of this Section is the specified minimum yield strength. If the specified minimum yield strength is not known, the yield strength is determined by performing all of the tensile tests of API Standard 5L on randomly selected test specimens with the following number of tests.

Pipe Size

Number of Tests

Less than 6 inches in outside diameter

One test for each 200 joints

6 inches through 12-3/4 inches in outside diameter

One test for each 100 joints

Larger than 12-3/4 inches in outside diameter

One test for each 50 joints

If the average yield-tensile ratio exceeds 0.85, the yield strength of the pipe is taken as 24,000 psi. If the average yield-tensile ratio is 0.85 or less, the yield strength of the pipe is taken as the lower of the following:

1. 80 percent of the average yield strength determined by the tensile tests;
2. the lowest yield strength determined by the tensile tests.
C. If the nominal wall thickness to be used in determining internal design pressure under Subsection A of this Section is not known, it is determined by measuring the thickness of each piece of pipe at quarter points on one end. However, if the pipe is of uniform grade, size, and thickness, only 10 individual lengths or 5 percent of all lengths, whichever is greater, need be measured. The thickness of the lengths that are not measured must be verified by applying a gage set to the minimum thickness found by the measurement. The nominal wall thickness to be used is the next wall thickness found in commercial specifications that is below the average of all the measurements taken. However, the nominal wall thickness may not be more than 1.14 times the smallest measurement taken on pipe that is less than 20 inches in outside diameter, nor more than 1.11 times the smallest measurement taken on pipe that is 20 inches or more in outside diameter.
D. The minimum wall thickness of the pipe may not be less than 87.5 percent of the value used for nominal wall thickness in determining the internal design pressure under Subsection A of this Section. In addition, the anticipated external loads and external pressures that are concurrent with internal pressure must be considered in accordance with §1311 and, after determining the internal design pressure, the nominal wall thickness must be increased as necessary to compensate for these concurrent loads and pressures.
E. The seam joint factor used in Subsection A of this Section is determined in accordance with the following table.

Specifications

Pipe Class

Seam Joint Factor

ASTM A53

Seamless

Electric resistance welded

Furnace lap welded

Furnace butt welded

1.00

1.00

0.80

0.60

ASTM A106

Seamless

1.00

ASTM A134

Electric fusion arc welded

0.80

ASTM A135

Electric resistance welded

1.00

ASTM A139

Electric fusion welded

0.80

ASTM A211

Spiral welded pipe

0.80

ASTM A333

Seamless

Welded

1.00

1.00

ASTM A381

Double submerged arc welded

1.00

ASTM A671

Electric-fusion-welded

1.00

ASTM A672

Electric-fusion-welded

1.00

ASTM A691

Electric-fusion-welded

1.00

API 5L

Seamless

Electric resistance welded

Electric flash welded

Submerged arc welded

Furnace lap welded

Furnace butt welded

1.00

1.00

1.00

1.00

0.80

0.60

1. The seam joint factor for pipe which is not covered by this Paragraph must be approved by the commissioner.
F. Piping systems designed for operation at high stress levels shall be analyzed for potential propagating fractures. Methods of limiting the extent of such fractures shall be applied where warranted.

La. Admin. Code tit. 43, § XI-1309

Promulgated by the Department of Natural Resources, Office of Conservation, LR 12:115 (February 1986).
AUTHORITY NOTE: Promulgated in accordance with R.S. 30:4(C)(17).