Current through Register Vol. 50, No. 11, November 20, 2024
Section XV-590 - Specific Requirements for Radiographic Personnel Performing Industrial RadiographyA. At a job site, the following shall be supplied by the licensee or registrant: 1. at least one operable, calibrated survey instrument;2. a current whole body personnel monitor (TLD or film badge) for each individual;3. an operable, calibrated pocket dosimeter with a range of 0 to 200 milliroentgens (5.16 x 10-5 C/kg) for each worker;4. an operable alarm ratemeter which meets the requirements of LAC 33:XV.577.H for each individual; and5. the appropriate barrier ropes and signs.B. Industrial radiographic operations shall not be performed if any of the items in LAC 33:XV.590.A are not available at the job site or are inoperable.C. Collimators shall be used in industrial radiographic operations that use crank-out devices and/or X-ray devices, except when physically impossible.D. No individual other than a radiographer or a radiographer trainee who is under the personal supervision of a radiographer instructor shall manipulate controls or operate equipment used in industrial radiographic operations. The radiographer trainee shall also be under the personal supervision of a radiographer instructor when using radiographic exposure devices, associated equipment, or a sealed source or while conducting radiation surveys required by LAC 33:XV.587 to determine that the sealed source has returned to its shielded position or the radiation machine is off after an exposure. The personal supervision must include: 1. the radiographer instructor's physical presence at the site where the sources of radiation are being used;2. the availability of the radiographer instructor to give immediate assistance if required; and3. the radiographer instructor's direct observation of the trainee's performance of the operations referred to in this Section.E. No individual shall act as a radiographer instructor unless such individual: 1. has met the requirements of LAC 33:XV.575.A;2. has one year of documented experience as a radiographer; and3. has been issued a radiographer certification card with instructor status by the department.F. During an inspection by the department, the department inspector may terminate an operation if any of the items of LAC 33:XV.590.A are not available and operable or if at least two radiographers are not present. Operations shall not be resumed until such conditions are met.La. Admin. Code tit. 33, § XV-590
Promulgated by the Department of Environmental Quality, Office of Air Quality and Radiation Protection, Radiation Protection Division, LR 20:653 (June 1994), amended LR 23:1139 (September 1997), amended by the Office of Environmental Assessment, Environmental Planning Division, LR 26:2584 (November 2000), LR 27:1237 (August 2001), LR 28:1952 (September 2002), LR 29:36 (January 2003), LR 29:1816 (September 2003), Amended by the Office of the Secretary, Legal Affairs and Criminal Investigations Division, LR 451757 (12/1/2019).AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2001 et seq. and 2104.B.