Current through Register Vol. 50, No. 11, November 20, 2024
Section XV-1757 - ReportsA. In addition to the reporting requirements in other parts of these regulations, the licensee shall report the following events if not reported under other parts of these regulations: 1. source stuck in an unshielded position;2. any fire or explosion in a radiation room;3. damage to the source racks;4. failure of the cable or drive mechanism used to move the source racks;5. inoperability of the access control system;6. detection of radiation source by the product exit monitor;7. detection of radioactive contamination attributable to licensed radioactive material;8. structural damage to the pool liner or walls;9. water loss or leakage from the source storage pool greater than the irradiator pool design parameters submitted by the licensee or applicant; and10. pool water conductivity exceeding 100 microsiemens per centimeter.B. The report shall include a telephone report within 24 hours, as described in LAC 33:XV.485.A, and a written report within 30 days, as described in LAC 33:XV.485.B.La. Admin. Code tit. 33, § XV-1757
Promulgated by the Department of Environmental Quality, Office of Air Quality and Radiation Protection, Radiation Protection Division, LR 24:2121 (November 1998).AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2001 et seq.