Current through Register Vol. 50, No. 11, November 20, 2024
Section V-30565 - How do I install cathodic protection on breakout tanks? [49 CFR 195.565]A. After October 2, 2000, when you install cathodic protection under §30563.A to protect the bottom of an aboveground breakout tank of more than 500 barrels (79.5 m3) capacity built to API Spec 12F (incorporated by reference, see §30107), API Std 620 (incorporated by reference, see §30107), or API Std 650 (incorporated by reference, see §30107) or API Std 650s predecessor, Standard 12C, you must install the system in accordance with ANSI/API RP 651 (incorporated by reference, see §30107). However, you dont need to comply with ANSI/API RP 651 when installing any tank for which you note in the corrosion control procedures established under §30402.C.3 why compliance with all or certain provisions of API RP 651 is not necessary for the safety of the tank. [ 49 CFR 195.565] La. Admin. Code tit. 33, § V-30565
Promulgated by the Department of Natural Resources, Office of Conservation, Pipeline Division, LR 29:2837 (December 2003), Amended LR 441030 (6/1/2018).AUTHORITY NOTE: Promulgated in accordance with R.S. 30:703.