Section V-3025 - Regulation of Residues
A residue derived from the burning or processing of hazardous waste in a boiler or industrial furnace is not excluded from the definition of a hazardous waste under LAC 33:V.105.D.2.d, h, and i unless the device and the owner or operator meet the following requirements.
A. The device meets the following criteria. 1. Boilers. Boilers must burn at least 50 percent coal on a total heat input or mass input basis, whichever results in the greater mass feed rate of coal.2. Ore or Mineral Furnaces. Industrial furnaces subject to LAC 33:V.105.D.2.h must process at least 50 percent by weight normal, nonhazardous raw materials.3. Cement Kilns. Cement kilns must process at least 50 percent by weight normal cement-production raw materials.B. The owner or operator demonstrates that the hazardous waste does not significantly affect the residue by demonstrating conformance with either of the following criteria. 1. Comparison of Waste-Derived Residue with Normal Residue. The waste-derived residue must not contain LAC 33:V.4901.G, Table 6 constituents (toxic constituents) that could reasonably be attributable to the hazardous waste at concentrations significantly higher than in residue generated without burning or processing of hazardous waste, using the following procedure. Toxic compounds that could reasonably be attributable to burning or processing the hazardous waste (constituents of concern) include toxic constituents in the hazardous waste, and the organic compounds listed in 40 CFR 266, Appendix VIII, as incorporated by reference in LAC 33:V.3099.Appendix H, that may be generated as products of incomplete combustion. For polychlorinated dibenzo-p-dioxins and polychlorinated dibenzo-furans, analyses must be performed to determine specific congeners and homologues, and the results converted to 2,3,7,8-TCDD equivalent values using the procedure specified in LAC 33:V.3099.Appendix I; a. Normal Residue. Concentrations of toxic constituents of concern in normal residue shall be determined based on analyses of a minimum of 10 samples representing a minimum of 10 days of operation. Composite samples may be used to develop a sample for analysis provided that the compositing period does not exceed 24 hours. The upper tolerance limit (at 95-percent confidence with a 95-percent proportion of the sample distribution) of the concentration in the normal residue shall be considered the statistically-derived concentration in the normal residue. If changes in raw materials or fuels reduce the statistically-derived concentrations of the toxic constituents of concern in the normal residue, the statistically-derived concentrations must be revised or statistically-derived concentrations of toxic constituents in normal residue must be established for a new mode of operation with the new raw material or fuel. To determine the upper tolerance limit in the normal residue, the owner or operator shall use statistical procedures prescribed in "Statistical Methodology for Bevill Residue Determinations" in 40 CFR 266, Appendix IX, as adopted and amended at LAC 33:V.3099.Appendix I;b. Waste-Derived Residue. Waste-derived residue shall be sampled and analyzed as often as necessary to determine whether the residue generated during each 24-hour period has concentrations of toxic constituents that are higher than the concentrations established for the normal residue under LAC 33:V.3025.B.1.a. If so, hazardous waste burning has significantly affected the residue and the residue shall not be excluded from the definition of a hazardous waste. Concentrations of toxic constituents of concern in the waste-derived residue shall be determined based on analysis of one or more samples obtained over a 24-hour period. Multiple samples may be analyzed and multiple samples may be taken to form a composite sample for analysis provided that the sampling period does not exceed 24 hours. If more than one sample is analyzed to characterize waste-derived residues generated over a 24-hour period, the concentration of each toxic constituent shall be the arithmetic mean of the concentrations in the samples. No results may be disregarded; or2. Comparison of Waste-Derived Residue Concentrations with Health-Based Limits a. Nonmetal Constituents. The concentration of each nonmetal toxic constituent of concern (specified in Paragraph B.1 of this Section) in the waste-derived residue must not exceed the health-based level specified in 40 CFR 266, Appendix VII, as incorporated by reference and amended in LAC 33:V.3099.Appendix G, or the level of detection, whichever is higher. If a health-based limit for a constituent of concern is not listed in 40 CFR 266, Appendix VII, as incorporated by reference and amended in LAC 33:V.3099.Appendix G, then a limit of 0.002 micrograms per kilogram or the level of detection (which must be determined by using appropriate analytical procedures), whichever is higher, shall be used. The levels specified in 40 CFR 266, Appendix VII (and the default level of 0.002 micrograms per kilogram or the level of detection for constituents as identified in 40 CFR 266, Appendix VII.Note 1, as incorporated by reference and amended in LAC 33:V.3099.Appendix G) are administratively stayed under the condition, for those constituents specified in Paragraph B.1 of this Section, that the owner or operator complies with alternative levels defined as the land disposal restriction limits specified in LAC 33:V.2299.Appendix, Table 2 for F039 nonwastewaters. In complying with those alternative levels, if an owner or operator is unable to detect a constituent despite documenting use of best good-faith efforts, as defined by applicable agency guidance or standards, the owner or operator is deemed to be in compliance for that constituent. Until new guidance or standards are developed, the owner or operator may demonstrate such good-faith efforts by achieving a detection limit for the constituent that does not exceed an order of magnitude above the level provided by LAC 33:V.2299.Appendix, Table 2 for F039 nonwastewaters. In complying with the LAC 33:V.2299.Appendix, Table 2 for F039 nonwastewater levels for polychlorinated dibenzo-p-dioxins and polychlorinated dibenzo-furans, analyses must be performed for total hexachlorodibenzo-p-dioxins, total hexachlorodibenzofurans, total pentachlorodibenzo-p-dioxins, total pentachlorodibenzofurans, total tetrachlorodibenzo-p-dioxins, and total tetrachlorodibenzofurans;
[NOTE to Subparagraph B.2.a: The stay, under the condition that the owner or operator complies with alternative levels defined as the land disposal restriction limits specified in LAC 33:V.2299.Appendix, Table 2 for F039 nonwastewaters, remains in effect until further administrative action is taken and notice is published in the Federal Register or the Louisiana Register.]
b. Metal Constituents. The concentration of metals in an extract obtained using the Toxicity Characteristic Leaching Procedure of LAC 33:V.4903.E must not exceed the levels specified in 40 CFR 266, Appendix VII, as adopted and amended at LAC 33:V.3099.Appendix G;c. Sampling and Analysis. Waste-derived residue shall be sampled and analyzed as often as necessary to determine whether the residue generated during each 24-hour period has concentrations of toxic constituents that are higher than the health-based levels. Concentrations of toxic constituents of concern in the waste-derived residue shall be determined based on analysis of one or more samples obtained over a 24-hour period. Multiple samples may be analyzed and multiple samples may be taken to form a composite sample for analysis provided that the sampling period does not exceed 24 hours. If more than one sample is analyzed to characterize waste-derived residues generated over a 24-hour period, the concentration of each toxic constituent shall be the arithmetic mean of the concentrations in the samples. No results may be disregarded.C. Records sufficient to document compliance with the provisions of this Section shall be retained until closure of the boiler or industrial furnace unit. At a minimum, the following shall be recorded: 1. levels of constituents in LAC 33:V.4901.G, Table 6 that are present in waste-derived residues;2. if the waste-derived residue is compared with normal residue under LAC 33:V.3025: a. the levels of constituents in LAC 33:V.4901.G, Table 6, that are present in normal residues; andb. data and information, including analyses of samples as necessary, obtained to determine if changes in raw materials or fuels would reduce the concentration of toxic constituents of concern in the normal residue.
La. Admin. Code tit. 33, § V-3025
Promulgated by the Department of Environmental Quality, Office of Solid and Hazardous Waste, Hazardous Waste Division, LR 18:1375 (December 1992), amended LR 21:266 (March 1995), LR 22:826 (September 1996), amended by the Office of Waste Services, Hazardous Waste Division, LR 24:1107 (June 1998), amended by the Office of Environmental Assessment, Environmental Planning Division, LR 27:300 (March 2001), repromulgated LR 27:513 (April 2001), amended by the Office of the Secretary, Legal Affairs Division, LR 34:1015 (June 2008), LR 34:1898 (September 2008).AUTHORITY NOTE: Promulgated in accordance with R.S. 30:2180 et seq.