Section 5-1-6 - Water flowmeter installation specifications(a) Each water flowmeter required by the chief engineer to be installed or required pursuant to a regulation adopted by the chief engineer, on or after the effective date of these regulations shall meet the following minimum water flowmeter installation specifications: (1) Each water flowmeter shall be installed in a manner that meets the following criteria: (A) Meets or exceeds the instructions of the manufacturer; and (B) except for a multijet and a positive displacement water flowmeter, is installed so that there are at least five pipe diameters of straight pipe upstream and at least two pipe diameters of straight pipe downstream of the sensor portion of the water flowmeter, regardless of the manufacturer's installation specifications. (2) Each water flowmeter shall be sized and installed so that full pipe flow will be maintained through the water flowmeter and so that water velocity in the measuring chamber will be within the normal operating range of the water flowmeter at all times while water is being diverted. (3) If a water flowmeter is located downstream of a water storage device, there shall be at least seven diameters of straight pipe upstream of the water storage device where a water flowmeter may be installed for a field test by the chief engineer. (4) Each water flowmeter shall be installed at a location at which the flowmeter measures all water diverted from the source of supply and does not measure water or other discharge, including tailwater and sewage effluent. (b) Each water flowmeter that is required by the chief engineer to be installed, or that was required to be installed as a condition of either an approval of application or an order of the chief engineer, or pursuant to a regulation adopted by the chief engineer, before the effective date of these regulations, shall meet the following minimum installation specifications: (1) Each water flowmeter shall be installed in a manner that meets or exceeds the instructions of the manufacturer and, except for a multijet and a positive displacement water flowmeter, shall be installed so that there are at least five pipe diameters of straight pipe upstream and at least two pipe diameters of straight pipe downstream of the sensor portion of the water flowmeter, regardless of the manufacturer's installation specifications. (2) Each water flowmeter shall be sized and installed so that full pipe flow will be maintained through the water flowmeter and so that water velocity in the measuring chamber will be within the normal operating range of the water flowmeter at all times while the water is being diverted. (3) Each water flowmeter shall be installed at a location at which the flowmeter measures all water diverted from the source of supply and does not measure water or other discharge, including tailwater and sewage effluent. Kan. Admin. Regs. § 5-1-6
Authorized by K.S.A. 82a-706a; implementing K.S.A. 82a-706a and K.S.A. 82a-706c; effective Sept. 22, 2000; amended Oct. 24, 2003.