Authority: IC 22-13-2-2; IC 22-13-2-2.5; IC 22-13-2-13
Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15; IC 36-7
Sec. 93.
Delete TABLE N1102.2.6 and substitute to read as follows:
TABLE N1102.2.6
STEEL FRAME CEILING, WALL AND FLOOR INSULATION R-VALUES
WOOD FRAME R-VALUE REQUIREMENTS | COLD-FORMED STEEL EQUIVALENT R-VALUEa |
Steel Truss Ceilingsa | |
R-30 | R-38 or R-30 + 3 or R-26 + 5 |
R-38 | R-49 or R-38 + 3 |
R-49 | R-38 + 5 |
Steel Joist Ceilingsb | |
R-30 | R-38 in 2 x 4 or 2 x 6 or 2 x 8; R-49 in any framing |
R-38 | R-49 in 2 x 4 or 2 x 6 or 2 x 8 or 2 x 10 |
Steel Framed Wall | |
R-13 | R-13 + 5 or R-15 + 4 or R-21 + 3 or R-0 + 10 |
R-15 | R-11 + 5 or R-13 + 4 or R-21 + 3 or R-0 + 15 |
R-19 | R-13 + 9 or R-19 + 8 or R-25 + 7 |
R-21 | R-13 +10 or R-19 + 9 or R-25 + 8 |
Steel Joist Floor | |
R-13 | R-19 in 2 x 6 or R-19 + R-6 in 2 x 8 or 2 x 10 |
R-19 | R-19 + R-6 in 2 x 6 or R-19 + R-12 in 2 x 8 or 2 x 10 |
For SI: 1 inch= 25.4 mm.
675 IAC 14-4.4-93