Sec. 190.
Change TABLE P3201.7 to read as follows:
TABLE P3201.7 | |
SIZE OF TRAPS FOR PLUMBING FIXTURES | |
PLUMBING FIXTURE | TRAP SIZE MINIMUM (inches) |
Bathtub (with or without shower head or whirlpool attachments) | 1 1/2 |
Bidet | 1 1/4 |
Clothes washer standpipe | 1 1/2a or 2 |
Dishwasher (on separate trap) | 1 1/2 |
Floor drain | 2 |
Kitchen sink (one or two traps, with or without dishwasher and food waste disposer) | 1 1/2 |
Laundry tub (one or more compartments) | 1 1/2 |
Lavatory | 1 1/4 |
Shower (based on the total flow rate through showerheads and bodysprays) | |
Flow rate: | |
5.7 gpm and less | 1 1/2 |
More than 5.7 gpm up to 12.3 gpm | 2 |
More than 12.3 gpm up to 25.8 gpm | 3 |
More than 25.8 gpm up to 55.6 gpm | 4 |
For SI: 1 inch = 25.4 mm, 1 gallon per minute = 3.785 L/m.