675 Ind. Admin. Code 14-4.4-12

Current through December 4, 2024
Section 675 IAC 14-4.4-12 - Section R309; garages and carports

Authority: IC 22-13-2-2; IC 22-13-2-2.5; IC 22-13-2-13

Affected: IC 22-12; IC 22-13; IC 22-14; IC 22-15; IC 36-7

Sec. 12.

Change SECTION R309 as follows:

(1) Add SECTION R309.6 after SECTION R309.5 to read as follows:

SECTION R309.6 DETACHED GARAGES, CARPORTS, AND ACCESSORY STRUCTURES.

Detached garages, carports, and accessory structures shall be constructed to applicable sections of this code unless otherwise noted in TABLE R309. Any habitable area located within a detached garage or accessory structure shall meet all applicable sections of this code and shall be provided with an exit door or window as specified in SECTION R310 and SECTION R311.

(2) Add TABLE R309 to the end of SECTION R309 to read as follows:

TABLE R309
DETACHED GARAGES, CARPORTS, AND ACCESSORY STRUCTURES
CONSTRUCTION REQUIREMENTS Portable 200 Square Feet Maximum Monolithic1 Footings 721 Square Feet Maximum Structures with Conventional Foundation
Footings and Foundations No Requirements 8" W x 18" D2 or 12" W x 12" D2 Indiana Residential Code
Floors No Requirements Indiana Residential Code
Exterior Walls No Requirements
Girders and Headers No Requirements
Roof Systems No Requirements
Electrical Power Limits One 20 Amp. Circuit
Water Supply/Sanitation Not Allowed 1
Permanent Heat Not Allowed 1
Maximum Number of Stories 1 13 3
NOTES:
1In structures utilizing monolithic floor systems, the water and sanitation systems and permanent heating facilities may be installed when approved flexible connections are provided.
26 x 6 - W2.9 x W2.9 welded wire fabric or equivalent is required when monolithic slab footing system is used.
3One story unless otherwise approved by the building official.

675 IAC 14-4.4-12

Fire Prevention and Building Safety Commission; 675 IAC 14-4.4-12; field 11/26/2019, 11:43 a.m.: 20191225-IR-675190330FRA