329 Ind. Admin. Code 11.6-6-1

Current through October 23, 2024
Section 329 IAC 11.6-6-1 - Operational requirements for processing of mobile homes or mobile home parts

Authority: IC 13-14-8-7; IC 13-15; IC 13-19-3

Affected: IC 13-30-2; IC 36-9-30

Sec. 1.

(a) A facility that processes or stores mobile homes or mobile home parts must have the following:
(1) A sign at least one (1) foot high by two (2) feet wide prominently displayed by the door or entrance to the facility and legibly containing the following information in letters at least one (1) inch high:
(A) The name of the facility.
(B) The IDEM registration number.
(C) The name and telephone number of a designated emergency contact person.
(2) Any liquids or leachate must be controlled and collected.
(3) Adequate measures must be in place to control fire hazards, and the contingency action plan required under 329 IAC 11.6-4-1(f)(13) must be submitted to the local fire department that services the area.
(4) A telephone, cellular telephone, or radio communication device available when employees are present.
(5) Access control to the facility.
(6) Adequate control of the following:
(A) Dust.
(B) Odors.
(C) Wastewater.
(D) Vectors.
(E) Litter.
(F) Leachate.
(7) Proper handling of gas tanks and refrigerants.
(8) Monitoring of incoming waste. Any waste that the facility is not registered to receive must be isolated and removed from the registered facility. Any putrescible waste must be properly disposed of within seventy-two (72) hours of being received at the registered facility. Any other solid waste that is not attached to the mobile home and is not recyclable must be removed and properly disposed of as soon as possible after being received at the facility.
(b) Any container or vehicle that is used to store or accumulate mobile home parts or residues that are:
(1) flammable;
(2) subject to blowing;
(3) a vector attraction; or
(4) noxious odor-producing;

must be closed at the end of the operating day.

(c) The owner or operator shall record and retain at the registered facility, or in an alternative location approved by the commissioner, all records, reports, or audits required by this article until certification of closure is deemed adequate by the commissioner under 329 IAC 11.6-8-1(f). The following information must be retained:
(1) A paper copy or an accessible copy of the electronically submitted registration.
(2) A contingency action plan as required under 329 IAC 11.6-4-1(f)(13).
(3) The records required under 329 IAC 11.6-5-1(b)(2).
(4) The training log required under subsection (f).
(5) The results of any waste determination tests on the residues generated by the registered facility.
(d) The following must be furnished as required and made available during normal operating hours for inspection by any officer, employee, or representative of the commissioner:
(1) All records required by this article.
(2) Any tests performed for a waste determination under 329 IAC 11.6-2-21.
(e) No hazardous waste that is regulated by 329 IAC 3.1 shall be processed at any registered facility, unless the facility is permitted under 329 IAC 3.1 to process hazardous waste.
(f) Employees must be trained on safety, emergency, and operational procedures for the facility. A training log must be retained at the registered facility for five (5) years stating the following:
(1) The name of the employee.
(2) Training topics.
(3) Hours of training.

329 IAC 11.6-6-1

Solid Waste Management Division; 329 IAC 11.6-6-1; filed Jan 30, 2013, 12:31 p.m.: 20130227-IR-329100253FRA