Section 327 IAC 20-5-5 - Liquid manure structure design requirements

Authority: IC 13-14-8-7; IC 13-15-2-1; IC 13-18-10.5

Affected: IC 13-11-2; IC 13-14; IC 13-15; IC 13-18; IC 13-30

Sec. 5.

(a) In addition to section 2 of this rule, a SMSS that contains liquid manure must be designed according to the Indiana NRCS Conservation Practice Standard Code 313: Waste Storage Structure, October 2016*.
(b) An uncovered SMSS containing liquid manure must be designed with a minimum freeboard of two (2) feet unless an alternate design is approved by the commissioner under section 6 of this rule.
(c) Test holes for an earthen SMSS storing liquid manure must be placed at a rate of two (2) holes for the first one-half (1/2) acre of storage and one (1) additional hole for each additional one-half (1/2) acre of storage.
(d) Pipelines must be constructed according to the Indiana NRCS Conservation Practice Standard Code 634: Waste Transfer, October 2015*.
(e) The SMSS must be certified upon completion by a registered professional engineer on a form provided by the department. The engineer's certification must be kept in the operating record and submitted to the department prior to introducing manure into the SMSS.

*These documents are incorporated by reference. Copies may be obtained from the Indiana NRCS State Office, 6013 Lakeside Boulevard, Indianapolis, IN 46278, online at http://nrcs.usda.gov/, or are available for review at the Indiana Department of Environmental Management, Office of Legal Counsel, Indiana Government Center North, Thirteenth Floor, 100 North Senate Avenue, Indianapolis, Indiana 46204.

327 IAC 20-5-5

Filed 9/28/2015, 11:13 a.m.: 20151028-IR-327130245FRA
Readopted filed May 18, 2021, 1:04 p.m.: 20210609-IR-327210118BFA
Filed 5/23/2022, 9:29 a.m.: 20220622-IR-327210028FRA