Authority: IC 13-14-8; IC 13-17-3
Affected: IC 13-15; IC 13-17
Sec. 15.
Source | Emission Unit Description | Emission Limit (lbs/hour) or Other Requirements | Emission Limit (lbs/MMBtu) |
(1) Indianapolis Power & | (A) Unit 1 | 330.0 | 0.15 |
Light - Petersburg | (B) Unit 2 | 621.6 | 0.15 |
Generating Station | (C) Unit 3 | 2,049.8 | 0.37 |
Source ID No. 00002 | (D) Unit 4 | 1,942.5 | 0.35 |
(E) Diesel Generators PB-2, PB-3, and PB-4 | 500 hour calendar year operating limit (each) | ||
(2) Hoosier Energy - Ratts | (A) Boiler 1 | 58 | 0.05 |
Source ID No. 00001 | (B) Boiler 2 | 58 | 0.05 |
(C) No. 2 Auxiliary Boiler | 1 | 0.05 |
Emission Unit Description | Emission Limit (lbs/hour - 30 day rolling average) | Emission Limit (lbs/MMBtu - 30 day rolling average) |
(1) Unit 1 | 263.0 | 0.12 |
(2) Unit 2 | 495.4 | 0.12 |
(3) Unit 3 | 1,633.7 | 0.29 |
(4) Unit 4 | 1,548.2 | 0.28 |
326 IAC 7-4-15