Authority: IC 13-14-8; IC 13-17-3
Affected: IC 13-15; IC 13-17
Sec. 2.
No facility subject to this rule (326 IAC 11-1) shall cause, suffer, or allow particulate matter to be emitted in excess of the amount shown in the following table.
Allowable Emissions from Foundry Cupolas | |
Process Weight Rate | Allowable Emission of Particulate Matter |
Lbs/Hr | Lbs/Hr |
1,000 | 3.05 |
2,000 | 4.70 |
3,000 | 6.35 |
4,000 | 8.00 |
5,000 | 9.65 |
6,000 | 11.30 |
7,000 | 12.90 |
8,000 | 14.00 |
9,000 | 15.50 |
10,000 | 16.65 |
12,000 | 18.70 |
16,000 | 21.60 |
18,000 | 22.80 |
20,000 | 24.00 |
30,000 | 30.00 |
40,000 | 36.00 |
50,000 | 42.00 |
60,000 | 48.00 |
70,000 | 49.00 |
80,000 | 50.50 |
90,000 | 51.60 |
100,000 | 52.60 |
326 IAC 11-1-2