105 Ind. Admin. Code 16-1-18

Current through January 8, 2025
Section 105 IAC 16-1-18 - As-built documentation

Authority: IC 8-23-2-6; IC 8-23-5-10

Affected: IC 8-23-5-10

Sec. 18.

(a) As-built plans must show the exact location and elevation and actual depth from the recorded elevation, commonly known as X, Y, Z coordinates, on both plans and profile.
(b) As-built plans shall be submitted both in hard copies and in an electronic format compatible with INDOT GIS standards. As-built plans must be submitted within ninety (90) calendar days of completion of construction.
(c) The operator shall provide GPS coordinates accurate within less than two (2) feet of all handhole and vault locations, and shall be no more than six (6) inches for conduit. Measurements shall be made approximately every fifty (50) feet. The coordinates shall be noted on the plans and in a single comma separated value file provided to the department. The file shall be supplied on a compact disk to the department, which includes the latitude and longitude of all handhole and vault locations in decimal degree format. Each record shall include the type of object, latitude, longitude, road name, direction of roadway travel, and nearest mile marker to the nearest tenth of a mile.
(d) Failure to provide as-builts in accordance with this section may result in no additional permits being issued until as-builts are provided to the department.

105 IAC 16-1-18

Indiana Department of Transportation; 105 IAC 16-1-18; emergency rule filed 12/16/2021, 12:43 p.m.: 20211222-IR-105210537ERA, eff Jan 1, 2022