Current through Register Vol. 49, No. 2, January 10, 2025
Section 812.308 - Leachate Management Systema) The application shall contain information to show how the applicant will comply with 35 Ill. Adm. Code 811.309, including the following information:1) Leachate disposal methods, including:A) The approved NPDES permit or, if the permit is pending, the NPDES permit application;B) Documentation to demonstrate that the offsite treatment works meets the requirements of 35 Ill. Adm. Code 811.309(e)(1); orC) Pretreatment authorization, if necessary from the offsite publicly owned treatment works pursuant to 35 Ill. Adm. Code 310.2) Design of tanks, lagoons, and all other treatment or storage units;3) A map showing the location of all units, piping and monitoring stations; and4) A description of the leachate monitoring system, including all parameters to be monitored and the location of the sampling points.b) The operator may include in the application a request for authorization to recycle leachate, if desired. The request shall be supported by information to demonstrate compliance with 35 Ill. Adm. Code 811.309(f), including:1) A demonstration that the unit satisfies the criteria of 35 Ill. Adm. Code 811.309(f)(1);2) Estimates of the expected volume of excess leachate, as defined in 35 Ill. Adm. Code 811.309(f)(3);3) A plan for the disposal of excess leachate as defined in 35 Ill. Adm. Code 811.309(f)(3);4) Layout and design of the leachate distribution system; and5) Pursuant to 35 Ill. Adm. Code 811.309(f)(6), a demonstration that the daily and intermediate cover is permeable, or a plan to remove daily and intermediate cover prior to additional waste disposal.Ill. Admin. Code tit. 35, § 812.308