Current through Register Vol. 48, No. 49, December 6, 2024
Section 724.119 - Construction Quality Assurance Programa) Construction Quality Assurance (CQA) Program 1) A CQA program is required for all surface impoundment, waste pile and landfill units that are required to comply with Sections 724.321(c) and (d), 724.351(c) and (d), and 724.401(c) and (d). The program must ensure that the constructed unit meets or exceeds all design criteria and specifications in the permit. The program must be developed and implemented under the direction of a CQA officer who is a registered professional engineer.2) The CQA program must address the following physical components, where applicable: C) Low-permeability soil liners;D) Geomembranes (flexible membrane liners);E) Leachate collection and removal systems and leak detection systems; andb) Written CQA Plan. The owner or operator of units subject to the CQA program under subsection (a) must develop and implement a written CQA plan. The plan must identify steps that will be used to monitor and document the quality of materials and the condition and manner of their installation. The CQA plan must include the following: 1) Identification of applicable units, and a description of how they will be constructed.2) Identification of key personnel in the development and implementation of the CQA plan, and CQA officer qualifications.3) A description of inspection and sampling activities for all unit components identified in subsection (a)(2), including observations and tests that will be used before, during and after construction to ensure that the construction materials and the installed unit components meet the design specifications. The description must cover: Sampling size and locations; frequency of testing; data evaluation procedures; acceptance and rejection criteria for construction materials; plans for implementing corrective measures; and data or other information to be recorded and retained in the operating record under Section 724.173.c) Contents of Program 1) The CQA program must include observations, inspections, tests and measurements sufficient to ensure the following: A) Structural stability and integrity of all components of the unit identified in subsection (a)(2);B) Proper construction of all components of the liners, leachate collection and removal system, leak detection system, and final cover system, according to permit specifications and good engineering practices and proper installation of all components (e.g., pipes) according to design specifications;C) Conformity of all materials used with design and other material specifications under Sections 724.321, 724.351, and 724.401.2) The CQA program must include test fills for compacted soil liners, using the same compaction methods as in the full scale unit, to ensure that the liners are constructed to meet the hydraulic conductivity requirements of Sections 724.321(c)(1)(A)(ii), 724.351(c)(1)(A)(ii), or 724.401(c)(1)(A)(ii) in the field. Compliance with the hydraulic conductivity requirements must be verified by using in-situ testing on the constructed test fill. The Agency must accept an alternative demonstration, in lieu of a test fill, where data are sufficient to show that a constructed soil liner will meet the hydraulic conductivity requirements of Sections 724.321(c)(1)(A)(ii), 724.351(c)(1)(A)(ii), or 724.401(c)(1)(A)(ii) in the field.d) Certification. Waste must not be received in a unit subject to Section 724.119 until the owner or operator has submitted to the Agency by certified mail or hand delivery a certification signed by the CQA officer that the approved CQA plan has been successfully carried out and that the unit meets the requirements of Sections 724.321(c) or (d), 724.351(c) or (d), or 724.401(c) or (d); and the procedure in 35 Ill. Adm. Code 703.247(b) has been completed. Documentation supporting the CQA officer's certification must be furnished to the Agency upon request.Ill. Admin. Code tit. 35, § 724.119
Amended at 27 Ill. Reg. 3725, effective February 14, 2003
Amended at 42 Ill. Reg. 22614, effective 11/19/2018