Ill. Admin. Code tit. 35 § 214.183

Current through Register Vol. 48, No. 43, October 25, 2024
Section 214.183 - General Formula
a) The general formula is:

E = (HA)0.11 (HE)2

________________________________

(in English units)

128

E = 0.04347 (HA)0.11(HE)2

(in Metric units)

b) Symbols used in the general formula mean the following:

E

=

Total allowable emission of sulfur dioxide (in lbs/hr or kg/hr) into the atmosphere in any one-hour period from all fuel combustion emission sources owned or operated by such person and located within a 1.6 km (1 mile) radius from the center point of any such emission source.

HA

=

Average actual stack height as determined by method outlined in Appendix C.

HE

=

Effective height of effluent release as determined by method outlined in Appendix C.

Ill. Admin. Code tit. 35, § 214.183

Amended at 30 Ill. Reg. 9671, effective May 15, 2006