Current through September 2, 2024
Section 58.01.01.835 - RULES FOR CONTROL OF RENDERING PLANTSNo person may allow, cause, or permit:
01.Cookers. The operation or use of any device, machine, equipment, or other contrivance to cook inedible animal or marine matter unless all gases, vapors, and gas entrained effluents from these processes are passed through condensers to remove all steam and other condensable materials. All noncondensibles, defined as gases and vapors from processes that are not condensed at standard temperature and pressure unless otherwise specified, passing through the condensers must then be incinerated at one thousand two hundred degrees Fahrenheit (1,200) for a minimum of three-tenths (0.3) seconds, or treated in an equally effective manner.02.Expellers. The installation or operation of an expeller unless it is properly hooded and all exhaust gases are ducted to odor control equipment.03.Plant Air. The installation or operation of a rendering plant unless plant ventilation air is collected and ducted to odor control equipment except if it can be demonstrated that without ducting plant ventilation air to the odor control equipment no noticeable odors from the plant can be detected at the property line.Idaho Admin. Code r. 58.01.01.835