Contaminant | MCLG (mg/L) |
Copper | 1.3 |
Lead | 0 (zero) |
Water systems shall collect at least one sample during each monitoring period specified in paragraph (7)(d) from the number of sites listed in the first column below ("# of Sites Standard Monitoring") of the table in this paragraph. A system conducting reduced monitoring under paragraph (7)(d)4. shall collect at least one sample from the number of sites specified in the second column ("# of Sites Reduced Monitoring") of the table in this paragraph during each monitoring period specified in paragraph (7)(d)4.. Such reduced monitoring sites shall be representative of the sites required for standard monitoring. States may specify sampling locations when a system is conducting reduced monitoring. The table is as follows:
System Size Population Served | Number of Sites Standard Monitoring | Number of Sites Reduced Monitoring |
100,001 or more | 100 | 50 |
10,001 to 100,000 | 60 | 30 |
3,301 to 10,000 | 40 | 20 |
501 to 3,300 | 20 | 10 |
101 to 500 | 10 | 5 |
100 or fewer | 5 | 5 |
Distribution System Tap Sampling Requirements for Water Quality Parameters. (Other Than Lead and Copper)
System Size Population Served | Number of Distribution Sampling Sites Base Monitoring |
100,001 or more | 25 |
10,001 to 100,000 | 10 |
3,301 to 10,000 | 3 |
501 to 3,300 | 2 |
101 to 500 | 1 |
100 or fewer | 1 |
System Size Population Served | Number of Distribution Sampling Sites Reduced Monitoring |
100,001 or more | 10 |
10,001 to 100,000 | 7 |
3,301 to 10,000 | 3 |
501 to 3,300 | 2 |
101 to 500 | 1 |
100 or fewer | 1 |
Ga. Comp. R. & Regs. R. 391-3-5-.25
O.C.G.A. § 12-5-170 et seq.