Current through Reg. 50, No. 244; December 17, 2024
Section 62-672.700 - Construction of New Phosphogypsum Stacks(1) Any new phosphogypsum stack or lateral expansion thereof as defined in subsection 62-673.200(9), F.A.C., shall be designed in accordance with the minimum standards of Chapter 62-673, F.A.C., with an overall factor of safety of 1.5 for any potential failure surface encompassing the impoundment on top of the stack and passing through the gypsum slope or bottom liner interfaces, or extending into earthen material in contact with the bottom liner.(2) The maximum height of a starter dike for new phosphogypsum stacks or lateral expansions thereof shall be equal to or lower than the height of the associated lined perimeter dike.Fla. Admin. Code Ann. R. 62-672.700
Rulemaking Authority 403.4155 FS. Law Implemented 403.4155 FS.