Fla. Admin. Code R. 25-30.055

Current through Reg. 50, No. 235-239, December 10, 2024
Section 25-30.055 - Systems with a Capacity or Proposed Capacity to Serve 100 or Fewer Persons
(1) A water or wastewater system is exempt under Section 367.022(6), F.S., if its current or proposed water or wastewater treatment facilities and distribution or collection system have and will have a capacity, excluding fire flow capacity, of no greater than 10, 000 gallons per day or if the entire system is designed to serve no greater than 40 equivalent residential connections (ERCs). For purposes of this rule only, one ERC equals 250 gallons per day.
(a) Unless the Commission determines that valid local statistical data should be used, ERCs for residential use are as follows:

Single family detached dwellings

1 ERC per unit

Multiple family dwellings

.8 ERC per unit

Mobile homes

.8 ERC per unit

(b) ERCs for nonresidential use shall be based on meter size and type as follows:
1. For Water Systems

Meter Size

Meter Type

ERCs

5/8''

Displacement

1.0

3/4''

Displacement

1.5

1''

Displacement

2.5

11/2''

Displacement or Turbine

5.0

2''

Displacement, Compound or Turbine

8.0

3''

Displacement

15.0

3''

Compound

16.0

3''

Turbine

17.5

4v

Displacement or Compound

25.0

4''

Turbine

30.0

6''

Displacement or Compound

50.0

6v

Turbine

62.5

8''

Compound

80.0

8''

Turbine

90.0

10''

Compound

115.0

10''

Turbine

145.0

12''

Turbine

215.0

2. For Wastewater Systems

Meter Size

Meter Type

ERCs

5/8''

Displacement

1.0

3/4''

Displacement

1.5

1''

Displacement

2.5

11/2''

Displacement or Turbine

5.0

2''

Displacement, Compound or Turbine

8.0

3''

Displacement

15.0

3''

Compound

16.0

3''

Turbine

17.5

4''

Displacement or Compound

25.0

4''

Turbine

30.0

6''

Displacement or Compound

50.0

6''

Turbine

62.5

8''

Compound

80.0

8''

Turbine

90.0

10''

Compound

115.0

10''

Turbine

145.0

12''

Turbine

215.0

(c) Where undeveloped land is adjacent to a system or proposed system the Commission may, where appropriate, estimate ERCs for service to future development on the adjacent undeveloped land. Unless the Commission determines that valid local statistical data should be used, ERCs for residential acreage should be estimated as follows:

Residential Use

ERCs/Acre

Mobile home

4.8

Detached single family

4.0

Estimates for other types of residential acreage and for commercial and industrial uses shall be made on a case by case basis.

Fla. Admin. Code Ann. R. 25-30.055

Rulemaking Authority 350.127(2), 367.121(1)(f) FS. Law Implemented 367.022(6) FS.

New 1-5-84, Formerly 25-10.10, 25-10.010, Amended 11-10-86.

New 1-5-84, Formerly 25-10.10, 25-10.010, Amended 11-10-86.