D.C. Mun. Regs. tit. 25, r. 25-C409

Current through Register Vol. 71, No. 49, December 6, 2024
Rule 25-C409 - CIRCULATION SYSTEMS - PUBLIC SWIMMING POOLS, TURNOVER RATES*
409.1

Circulation systems for pools shall comply with Section 311 of the 2012 International Swimming Pool and Spa Code (ISPSC) and this section.

409.2

Circulation equipment shall be sized to turn over the entire water capacity of the pool as specified in Table 407.2 of the 2012 International Swimming Pool and Spa Code (ISPSC). The system shall be designed to provide the required turnover rate based on the maximum pressure and flow rate recommended by the manufacturer for the filter and clean filter media.

TABLE 407.2 TURNOVER RATE

Swimming Pool Category

Turnover rate In Iiours

Class A, B, and C pools

Hours equal 1-1/2 times the average depth of pool m feet not to exceed 6 hours

Wading pools

1

D.C. Mun. Regs. tit. 25, r. 25-C409

Final Rulemaking published at 64 DCR 5359 (6/9/2017)