Strike Section 409.1 of the International Green Construction Code in its entirety and insert new Section 409.1 in the Green Construction Code in its place to read as follows:
Light pollution control. Uplight, light trespass, glare, and color temperature shall be limited for all exterior lighting equipment as described in Sections 409.2, 409.3, and 409.4. The provisions of this section shall only apply to new construction and Level 3 alterations complying with the applicable requirements of the Existing Building Code.
Exceptions: Lighting used for the following exterior applications is exempt where equipped with a control device independent of the control of the non-exempt lighting:
Strike Section 409.1.1 and Table 409.1.1 of the International Green Construction Code in their entirety and insert new Section 409.1.1 and Table 409.1.1 in the Green Construction Code in their place to read as follows:
Exterior lighting zones. The lighting zone for the building site shall be determined from Table 409.1.1 as clarified by Administrative Bulletins.
TABLE 409.1.1 EXTERIOR LIGHTING ZONES
LIGHTING ZONE | DESCRIPTION |
1 | Developed areas of national parks, state parks, forest land and rural areas |
2 | Areas predominantly consisting of residential zoning, neighborhood business districts, light industrial with limited nighttime use and residential mixed use areas |
3 | All other areas (not included in other zones) |
4 | High-activity commercial districts |
Strike Section 409.2 and Table 409.2 of the International Green Construction Code in their entirety and insert new Section 409.2 and Table 409.2 in the Green Construction Code in their place to read as follows:
Uplight. Exterior lighting shall comply with the requirements of Table 409.2 for the exterior lighting zones (LZ) appropriate to the building site.
Exceptions: Lighting used for the following exterior applications shall be exempt from the requirements of Table 409.2:
TABLE 409.2 UPLIGHT RATINGS a, b
LIGHTING ZONE (LZ) 1 2 3 4 | ||||
Maximum luminaire uplight rating | U0 | U1 | U2 | U3 |
[no change to Section 409.3]
Insert a new Section 409.4 in the Green Construction Code to read as follows:
Color Temperature. Maximum color temperature for lights complying with Section 409 shall be 3000 degrees Kelvin or lower.
D.C. Mun. Regs. tit. 12, r. 12-K409