D.C. Mun. Regs. tit. 12, app 12-H-N r. 12-H-N102

Current through Register Vol. 71, No. 49, December 6, 2024
Rule 12-H-N102 - DEFINITIONS

EXIT. That portion of a means of egress system between the exit access and the exit discharge or public way. Exit components include exterior exit doors at the level of exit discharge, interior exit stairways, interior exit ramps, exit passageways, exterior exit stairways and exterior exit ramps and horizontal exits.

EXIT ACCESS. That portion of a means of egress system that leads from any occupied point in a building or structure to an exit.

EXIT DISCHARGE, LEVEL OF. The story at the point at which the exit terminates and the exit discharge begins.

MEANS OF EGRESS.A continuous and unobstructed path of vertical and horizontal egress travel from any occupied portion of a building or structure to the exterior at grade. A means of egress consists of three separate and distinct parts: the exit access, the exit and the exit discharge.

Exception: One and two family dwelling units used as a home day care occupancy where the occupancy is equipped throughout with an automatic sprinkler system in accordance with Section R313 of the Residential Code or Section 903.2.8 of the Fire Code, as applicable,need only provide an exit door that provides direct access to the exterior.

D.C. Mun. Regs. tit. 12, app 12-H-N r. 12-H-N102

Final Rulemaking published at 67 DCR 5679 (5/29/2020)