D.C. Mun. Regs. tit. 11, r. 11-K403

Current through Register Vol. 71, No. 49, December 6, 2024
Rule 11-K403 - HEIGHT (HE)
403.1

The maximum permitted building height and number of stories, not including the penthouse or rooftop structure, in HE shall be given in the following table:

TABLE K § 403.1: MAXIMUM PERMITTED HEIGHT AND STORIES

HE Sub-DistrictBuilding Height Minimum MaximumNo. of Stories
HE-1 (19th St.) 26 ft. 50 ft. 4
HE-2 (20th St.) 40 ft. 80 ft. 7
HE-3 (Water St.) 80 ft. 110 ft. 10
HE-4 (Corrections) - 90 ft. 8
Square E (Park) - 26 ft. -

403.2

Building height shall be measured from the lowest curb level along a street frontage abutting the lot.

403.3

A hospital located in the HE-2 zone may exceed eighty feet (80 ft.) in height, to a maximum of one hundred ten feet (110 ft.), if approved as a special exception by the Zoning Commission pursuant to Subtitle K § 416.

403.4

Penthouses and rooftop structures shall be subject to the regulations of Subtitle C, Chapter 15, and the height and story limitations specified in Subtitle K § 403.5.

403.5

The maximum permitted height of a penthouse or rooftop structure, except as limited in Subtitle C § 1501 on the roof of a detached dwelling, semi-detached dwelling, rowhouse, or flat shall be as set forth in the following table:

TABLE K § 403.5: MAXIMUM PERMITTED PENTHOUSE OR ROOFTOP STRUCTURE HEIGHT AND STORIES

ZONE DISTRICTMaximum Penthouse HeightMaximum Penthouse Stories
HE-1 12 ft. except

15 ft. for penthouse mechanical space

1; second story permitted for penthouse mechanical space
HE-2 20 ft. 1; second story permitted for penthouse mechanical space
HE-3, HE-4 20 ft. 1 plus mezzanine; second story permitted for penthouse mechanical space

403.6

The matter-of-right height shall serve as the maximum permitted height, penthouse and rooftop structure height, and floor area ratio for a PUD.

D.C. Mun. Regs. tit. 11, r. 11-K403

Final Rulemaking published at 63 DCR 2447 (9/6/2016); amended by Final Rulemaking published at 68 DCR 13834 (12/24/2021)