D.C. Mun. Regs. tit. 11, r. 11-K219

Current through Register Vol. 71, No. 49, December 6, 2024
Rule 11-K219 - COURT (SEFC-2)
219.1

Where a court is provided, it shall have the following minimum dimensions:

TABLE K § 219.1: MINIMUM COUTYARD DIMENSIONS

Type of StructureMinimum Width Open CourtMinimum Width Closed CourtMinimum Area Closed Court
Residential (except hotel): 4 in./ft. of height of court;

10 ft. minimum.

4 in./ft. of height of court;

15 ft. minimum.

Twice the square of the required width of court dimension;

350 sq. ft. minimum.

Non-Residential and Lodging: 2.5 in./ft. of height of court;

6 ft. minimum.

2.5 in./ft. of height of court;

12 ft. min.

Twice the square of the required width of court dimension;

250 sq. ft. minimum.

D.C. Mun. Regs. tit. 11, r. 11-K219

Final Rulemaking published at 63 DCR 2447 (9/6/2016)