where:
E h = Total organic mass flow rate, kg/h;
Q2sdVolumetric flow rate of gases entering or exiting control device, as determined by Method 2, dscm/h;
n = Number of organic compounds in the vent gas;
Ci = Organic concentration in ppm, dry basis, of compound i in the vent gas, as determined by Method 18;
MW i = Molecular weight of organic compound i in the vent gas, kg/kg-mol;
0.0416 = Conversion factor for molar volume, kg-mol/m3 (@ 293 K and 760 mm Hg);
10-6 = Conversion from ppm.
Eh = (Q)(C)(MW)(0.0416)(10-6)
Where:
Eh = Total organic mass flow rate, kg/h;
Q = Volumetric flow rate of gases entering and exiting control device, as determined by Method 2, dscm/h
C = Organic concentration in ppm, dry basis; as determined by Method 25A
MW = Molecular weight of propane, 44;
0.0416 = Conversion factor for molar volume, kg-mol/m3 (@ 293 K and 70 mm Hg);
10-6 = conversion from ppm.
where:
(Amended January 1, 1999)
7 Del. Admin. Code § 1302-264-AA-264.1034