Table 1. Hostels, Travel Trailer (Dependent Trailer) And Residential Camps - Except Day Camps*
Water Closets | Urinals | Lavatories | Showers | Drinking Fountain |
Male Female | # of Males# of Fixtures | # of persons/# of fixtures | 1 per 8 persons | 1 fixture for each 75 persons |
1/10 1/8 | 1-150 1 per 25 | |||
Over 10, add 1 fixture for each 25 males, and 1 for each 20 females | Over 150, add 1 fixture for each 50 males | 1-12 fixtures for each 20 males and 1 for each 15 females/ 1 | Additional fixtures shall be installed at the ratio of one per 30 persons | |
Over 150 persons, add 1 fixture for each persons |
All new construction must meet the following requirements of the State Plumbing Code:
Water Closets | Urinals | Lavatories | Lavatories | Drinking Fountain |
1 per 10 | shall not be substituted for more than 50% of the required water closets. | 1 per 10 | 1 per 8 | 1 per 100 |
Flush urinals or urinals specifically designed for females may be substituted for not more than one-half the required number of toilet facilities.
Table 2. Day Camps*
Water Closets | Urinals | Lavatories | Drinking Fountains |
Male Female | 1 per 30 males | 1 per 30 | 1 per 40 |
1/60 1/35 | |||
All new construction must meet the following requirements of the State Plumbing Code:
Water Closets | Lavatories | Drinking Fountains |
1 per 15 | 1 per 15 | 1 per 100 |
Table 3. Travel Trailers (Self-contained)
One flush toilet, one lavatory, and one sanitary station/100 parking spaces. The station is to utilize a foot operated seal to cover the sewer pipe inlet when it is not in use. That station is also to have water available to wash any spillage into the drain, and a concrete 4'0" x 8'0" platform that is designed to slope to the sewage inlet. The wash down hose is to be protected against backflow. |
16 Del. Admin. Code § 4467-15.0