16.1 Each licensee or registrant shall make, or cause to be made, surveys that:
16.1.1 Are necessary for the licensee or registrant to comply with Part D; and
16.1.2 Are necessary under the circumstances to evaluate:
16.1.2.1 The magnitude and extent of radiation levels;
16.1.2.2 Concentrations or quantities of radioactive material; and
16.1.2.3 The potential radiological hazards.
16.2 The licensee or registrant shall ensure that instruments and equipment used for quantitative radiation measurements, for example, dose rate and effluent monitoring, are calibrated at intervals not to exceed 12 months for the radiation measured, except when a more frequent interval is specified in another applicable Part of these regulations or a license condition.
16.3 All personnel dosimeters, except for direct and indirect reading pocket ionization chambers and those dosimeters used to measure the dose to any extremity, that require processing to determine the radiation dose and that are used by licensees and registrants to comply with Section 6.0, with other applicable provisions of these regulations, or with conditions specified in a license or registration shall be processed and evaluated by a dosimetry processor:
16.3.1 Holding current personnel dosimetry accreditation from the National Voluntary Laboratory Accreditation Program of the National Institute of Standards and Technology; and
16.3.2 Approved in this accreditation process for the type of radiation or radiations included in the National Voluntary Laboratory Accreditation Program that most closely approximates the type of radiation or radiations for which the individual wearing the dosimeter is monitored.
16.4 The licensee or registrant shall ensure that adequate precautions are taken to prevent a deceptive exposure of an individual monitoring device.

16 Del. Admin. Code § 4465-D-16.0

19 DE Reg. 140(8/1/2015)
22 DE Reg. 401( 11/1/2018) (Final)