The owner or operator of a bumped-up RACT unit shall comply with the applicable Phase 2 emission limitations of this subsection in accordance with the applicable timing set forth in subsection (n) of this section.
Gas-fired (lb/MMBtu) | Residual oil-fired (lb/MMBtu) | Other oil-fired (lb/MMBtu) | Coal-fired (lb/MMBtu) | |
Cyclone boiler | 0.30 | 0.43 | 0.43 | *** |
Other boiler | 0.20 | 0.25 | 0.20 | 0.28 |
Gas-fired (lb/MMBtu) | Residual oil-fired (lb/MMBtu) | Other oil-fired (lb/MMBtu) | Coal-fired (lb/MMBtu) | |
Ozone season limit (5 month average) | 0.10 | 0.20 | 0.10 | 0.15 |
Non-ozone season limit (7 month average) | 0.15 | 0.15 | 0.15 | 0.15 |
Gas-fired (lb/MMBtu) | Residual oil-fired (lb/MMBtu) | Other oil-fired (lb/MMBtu) | Coal-fired (lb/MMBtu) | |
Boiler serving an EGU | 0.10 | 0.20 | 0.10 | 0.12 |
Gas-fired (lb/MMBtu) | Residual oil-fired (lb/MMBtu) | Other oil-fired (lb/MMBtu) | Coal-fired (lb/MMBtu) | |
Non-ozone season limit (7 month average) | 0.15 | 0.15 | 0.15 | 0.15 |
Gas-fired (lb/MMBtu) | Residual oil-fired (lb/MMBtu) | Other oil-fired (lb/MMBtu) | |
Boilers with a maximum rated capacity greater than or equal to 5 MMBtu/hr | 0.20 | 0.25 | 0.20 |
Gas-fired (lb/MMBtu) | Residual oil-fired (lb/MMBtu) | Other oil-fired (lb/MMBtu) | |
Ozone season limit (5 month average) | 0.10 | 0.20 | 0.15 |
Non-ozone season limit (7 month average) | 0.15 | 0.15 | 0.15 |
Gas-fired (lb/MMBtu) | Residual oil-fired (lb/MMBtu) | Other oil-fired (lb/MMBtu) | |
Boilers with a maximum rated capacity greater than or equal to 5 and less than 25 MMBtu/hr | 0.20 | 0.25 | 0.20 |
Boilers with a maximum rated capacity greater than or equal to 25 MMBtu/hr and less than 100 MMBtu/hr | 0.05 | 0.20 | 0.10 |
Boilers with a maximum rated capacity of greater than or equal to 100 MMBtu/hr | 0.10 | 0.20 | 0.15 |
Gas-fired (lb/MMBtu) | Residual oil-fired (lb/MMBtu) | Other oil-fired (lb/MMBtu) | |
Non-ozone season limit (7 month average) | 0.15 | 0.15 | 0.15 |
Gas-fired | Other oil-fired | |
Simple cycle combustion turbine | 55 ppmvd | 75 ppmvd |
Gas-fired | Other oil-fired | |
Ozone season limit (5 month average) | 50 ppmvd or 0.18 lb/MMBtu | 50 ppmvd or 0.19 lb/MMBtu |
Non-ozone season limit (7 month average) | 0.15 lb/MMBtu | 0.15 lb/MMBtu |
Gas-fired | Other oil-fired | |
Simple cycle combustion turbine | 40 ppmvd | 50 ppmvd |
Other oil-fired | |
Non-ozone season limit (7 month average) | 0.15 lb/MMBtu |
Gas-fired | Other oil-fired | |
Combined cycle combustion turbine | 42 ppmvd | 65 ppmvd |
Gas-fired | Other oil-fired | |
Non-ozone season limit (7 month average) | 0.15 lb/MMBtu | 0.15 lb/MMBtu |
Gas-fired | Other oil-fired | |
Combined cycle combustion turbine | 25 ppmvd | 42 ppmvd |
Gas-fired | Other oil-fired | |
Non-ozone season limit (7 month average) | 0.15 lb/MMBtu | 0.15 lb/MMBtu |
Gas-fired (g/bk hp-hr) | Other oil-fired (g/bk hp-hr) | Landfill gas or digester gas, alone or fired with gas (g/bk hp-hr) | |
Reciprocating engine | 2.5 | 8.0 | 2.5 |
Gas-fired (g/bk hp-hr) | Other oil-fired (g/bk hp-hr) | Landfill gas or digester gas, alone or fired with gas (g/bk hp-hr) | |
Rich burn reciprocating engine | 1.5 | 1.5 | 2.0 |
Lean burn reciprocating engine | 1.5 | 2.3 | 2.0 |
or,
Conn. Agencies Regs. § 22a-174-22e