Washer Type | Minimum Modified Energy Factor | Maximum Water Factor |
Front loading [LESS THAN]3.5 cubic foot clothes container compartment capacity | 1.26 | 9.5 |
Top loading [LESS THAN]1.6 cubic foot clothes container compartment capacity | 0.65 | 9.5 |
Top loading =1.6 cubic foot and [LESS THAN]4.0 cubic foot clothes container compartment capacity | 1.26 | 9.5 |
Refrigerator/Freezer Type | Doors | Maximum Daily Energy Consumption kWh* |
Reach-in cabinets, pass- through cabinets, and roll-in or roll-through cabinets that are refrigerators | Solid | 0.125V + 2.76 |
Transparent | 0.172V + 4.77 | |
Reach-in cabinets, pass-through cabinets, and roll-in or roll-through cabinets that are freezers | Solid | 0.398V + 2.28 |
Transparent | 0.940V + 5.10 | |
Reach-in cabinets that are refrigerator/freezers | Solid | 0.273AV + 1.65 |
*Where V= Volume in Cubic Feet, and AV = Adjusted volume + refrigerator volume. |
Standard | Requirement |
Input Power | [LESS THAN]5 watts per face |
Luminance contrast | [LESS THAN]0.8 |
Minimum luminance | [GREATER THAN]8.6 caldelas/square meter measured at normal (0°) and 45° viewing angles |
Average luminance | [GREATER THAN]15 caldelas/square meter measured at normal (0°) and 45° viewing angles |
Maximum to minimum luminance ratio | [LESS THAN]20:1 measured at normal (0°) and 45° viewing angles |
Capacity | Type | Minimum Energy Efficiency Ratio |
=760,000 BTUs per hour | Units using both electric heat and air conditioning or units solely using electric air conditioning | 10.0 |
Units using both natural gas heat and electric air conditioning | 9.8 | |
=761,000 BTUs per hour | Units using both electric heat and air conditioning or units solely using electric air conditioning | 9.7 |
Units using both natural gas heat and electric air conditioning | 9.5 |
Single Phase | Three Phase | ||||||
Rated Power kVa | Output | Minimum % | Efficiency | Rated Power kVa | Output | Minimum % | Efficiency |
= 15 | [LESS THAN]25 | 97.7 | = 15 | [LESS THAN]30 | 97.0 | ||
= 25 | [LESS THAN]37.5 | 98.0 | = 30 | [LESS THAN]45 | 97.5 | ||
= 37.5 | [LESS THAN]50 | 98.2 | = 45 | [LESS THAN]75 | 97.7 | ||
= 50 | [LESS THAN]75 | 98.3 | = 75 | [LESS THAN]112.5 | 98.0 | ||
= 75 | [LESS THAN]100 | 98.5 | = 112.5 | [LESS THAN]150 | 98.2 | ||
= 100 | [LESS THAN]167 | 98.6 | = 150 | [LESS THAN]225 | 98.3 | ||
= 167 | [LESS THAN]250 | 98.7 | = 225 | [LESS THAN]300 | 98.5 | ||
= 250 | [LESS THAN]333 | 98.8 | = 300 | [LESS THAN]500 | 98.6 | ||
333 | 98.9 | = 500 | [LESS THAN]750 | 98.7 | |||
= 750 | [LESS THAN]1000 | 98.8 | |||||
1000 | 98.9 |
Type | Red | Amber | Green | |||
At 25°C (77°F) | At 74°C (165.2°F) | At 25°C (77°F) | At 74°C (165.2°F) | At 25°C (77°F) | At 74°C (165.2°F) | |
300 mm circular | 11 watts | 17 watts | 22 watts | 25 watts | 15 watts | 15 watts |
200 mm circular | 8 watts | 13 watts | 13 watts | 16 watts | 12 watts | 12 watts |
300 mm arrow | 9 watts | 12 watts | 10 watts | 12 watts | 11 watts | 11 watts |
Lane control (X) | 9 watts | 12 watts | No requirement | No requirement | ||
Lane control (Arrow) | No requirement | No requirement | 11 watts | 11 watts |
The power consumption of traffic signal lamps shall be not greater than 25 watts.
Type of Equipment | Annual Fuel Utilization Efficiency | Electricity Ratio |
Gas and propane furnaces | [GREATER THAN]= 90% | -- |
Oil furnaces | [GREATER THAN]= 83% | -- |
Gas and propane boilers | [GREATER THAN]= 84% | -- |
Oil-fired hot water boilers | [GREATER THAN]= 84% | -- |
Gas and propane steam boilers | [GREATER THAN]= 82% | -- |
Oil-fired steam boilers | [GREATER THAN]= 82% | -- |
Furnaces with furnace air handlers except for oil furnaces of [LESS THAN]94,000 BTU/hour capacity | -- | [LESS THAN]= 2.0 |
Oil furnaces [LESS THAN]94,000 BTU/hour capacity with furnace air handlers | -- | [LESS THAN]= 2.3 |
The efficiency in the active mode of power supplies when tested at 115 volts at 60 Hz, shall not be less than the applicable values shown (expressed as the decimal equivalent of a percentage); and the energy consumption in the no-load mode of power supplies when tested at 115 volts at 60 Hz shall not be greater than the values shown in the following table:
Nameplate Output | Minimum Efficieny - Active Mode |
0 to less than 1 watt | 0.49* nameplate output |
[GREATER THAN]= 1 and [LESS THAN]= 49 watts | 0.09* Ln(nameplate output) + 0.49 |
[GREATER THAN] 49 watts | 0.84 |
Maximum Energy Consumption - No-Load Mode | |
0 to [LESS THAN] 10 watts | 0.5 watts |
[GREATER THAN]= 10 and [LESS THAN]= 250 watts | 0.75 watts |
Where Ln (Nameplate output) = Natural logarithm of the nameplate output expressed in watts |
Exceptions:
Nominal Lamp Wattage | Minimum Average Lamp Efficacy, Lumens per Watt |
40-50 | 10.5 |
51-66 | 11.0 |
67-85 | 12.5 |
86-115 | 14.0 |
116-155 | 14.5 |
156-205 | 15.0 |
Exceptions:
Motor Type | Required Components |
All | Automatic door closers that firmly close all reach-in doors |
All | Automatic door closers on all doors no wider than four foot or higher than seven foot, that firmly close walk-in doors that have been closed to within one inch of full closure. |
All | Envelope insulation [GREATER THAN]R-28 for refrigerators |
All | Envelope insulation [GREATER THAN]R-36 for freezers |
Condenser fan motors [LESS THAN]1 hp | Electronicaly commutated motors; permanent split capacitor-type motors; or polyphase motors[GREATER THAN] 1/2 hp |
Single-phase evaporator fan motors [LESS THAN]1 HP and [LESS THAN]460 volts | Electronically commutated motors |
Conn. Agencies Regs. § 16a-48-4