Current through Register 1536, December 6, 2024
Sinks shall comply with the following:
32.7.1Clear floor space: A clear floor space, complying with 521 CMR 6.3, Wheelchair Turning Space shall be provided in front of a sink to allow forward approach. The clear floor space shall be on an accessible route and shall extend a maximum of 19 inches (19" = 483mm) underneath the sink. See Fig. 30g.32.7.2 Sinks shall be mounted with the rim no higher than 34 inches (34" = 864mm) above the finish floor.32.7.3 Sink depth shall not exceed eight inches (8" = 203mm).32.7.4 Sink traps and drains shall be located as close to rear walls as possible. Plumbing pipes shall be recessed, insulated, or guarded. There shall be no sharp or abrasive surfaces under sinks.32.7.5 Faucets shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. Lever-operated, push-type, touch-type, or electronically controlled mechanisms are acceptable designs.32.7.6 Garbage disposals, when provided, shall be controlled by switches under the counter at the front.