Table 1-Requalification Intervals of UN Pressure Receptacles
Interval (years) | UN pressure receptacles/hazardous materials |
10 | Pressure receptacles for all hazardous materials except as noted below (also for dissolved acetylene, see paragraph (d)(3) of this section): |
5 | Composite pressure receptacles. |
5 | Metal hydride storage systems |
5 | Pressure receptacles used for: All Division 2.3 materials. UN1013, Carbon dioxide. |
UN1043, Fertilizer ammoniating solution with free ammonia. UN1051, Hydrogen cyanide, stabilized containing less than 3% water. UN1052, Hydrogen fluoride, anhydrous. UN1745, Bromine pentafluoride. | |
UN1746, Bromine trifluoride. UN2073, Ammonia solution. UN2495, Iodine pentafluoride. UN2983, Ethylene Oxide and Propylene oxide mixture, not more than 30% ethylene oxide. | |
5 | Pressure receptacles used for adsorbed gases. |
49 C.F.R. §180.207