Current through September 30, 2024
Section 174.200 - Special handling requirements(a) Division 2.1 (flammable gas) materials may not be loaded, transported, or stored in a rail car equipped with any type of lighted heater or open-flame device, or in a rail car equipped with any apparatus or mechanism utilizing an internal combustion engine in its operation.(b) Division 2.1 (flammable gas) materials may not be loaded in a truck body or trailer equipped with any type of lighted heater or any automatic heating or refrigerating apparatus when such truck bodies or trailers are loaded on flatcars except as provided in paragraph (c) of this section.(c) Heating or refrigeration apparatus may be operated on a motor vehicle loaded on a flatcar when the motor vehicle is loaded with Division 2.1 (flammable gas) materials only if: (1) The lading space is not equipped with any electrical apparatus that is not non-sparking or explosion-proof;(2) There is no combustion apparatus in the lading space;(3) There is no connection for the return of air from the lading space to any combustion apparatus; and(4) The heating system conforms to § 393.77 of this title and does not heat any part of the lading over 54 °C (129 °F).(d) For a single train of 20 or more loaded tank cars of Methane, refrigerated liquid in a continuous block or a single train carrying 35 or more loaded tank cars of Methane, refrigerated liquid throughout the train consist, each carrier must ensure the train is equipped and operated with either a two-way end-of-train (EOT) device, as defined in 49 CFR 232.5 , or a distributed power (DP) system, as defined in 49 CFR 229.5 .Amdt. 174-26, 41 FR 16092, Apr. 15, 1976, as amended by Amdt. 174-68, 55 FR 52682, Dec. 21, 1990; 56 FR 66281, Dec. 20, 1991; 85 FR 45030, July 24, 2020