Current through October 31, 2024
Section 90.221 - Adjacent channel power limits(a) For the frequency bands indicated below, operations using equipment designed to operate with a 25 kHz channel bandwidth may be authorized up to a 22 kHz bandwidth if the equipment meets the adjacent channel power (ACP) limits below. The table specifies a value for the ACP as a function of the displacement from the channel center frequency and a measurement bandwidth of 18 kHz.(b)(1) Maximum adjacent power levels for frequencies in the 450-470 MHz band: Frequency offset | Maximum ACP (dBc) for devices 1 watt and less | Maximum ACP (dBc) for devices above 1 watt |
25 kHz | -55 dBc | -60 dBc |
50 kHz | -70 dBc | -70 dBc |
75 kHz | -70 dBc | -70 dBc |
(2) In any case, no requirement in excess of -36 dBm shall apply.(c)(1) Maximum adjacent power levels for frequencies in the 809-824/854-869 MHz band: Frequency offset | Maximum ACP (dBc) for devices less than 15 watts | Maximum ACP (dBc) for devices 15 watts and above |
25 kHz | -55 dBc | -55 dBc |
50 kHz | -65 dBc | -65 dBc |
75 kHz | -65 dBc | -70 dBc |
(2) In any case, no requirement in excess of -36 dBm shall apply.(d) On any frequency removed from the assigned frequency by more than 75 kHz, the attenuation of any emission must be at least 43 + 10 log (Pwatts) dB. 77 FR 61538 , Oct. 10, 2012