47 C.F.R. § 18.305

Current through October 31, 2024
Section 18.305 - Field strength limits
(a) ISM equipment operating on a frequency specified in § 18.301 is permitted unlimited radiated energy in the band specified for that frequency.
(b) The field strength levels of emissions which lie outside the bands specified in § 18.301 , unless otherwise indicated, shall not exceed the following:

Equipment Operating frequencyRF Power generated by equipment (watts)Field strength limit (uV/m) Distance (meters)
Any type unless otherwise specified (miscellaneous)Any ISM frequencyBelow 500
500 or more
25
25 * SQRT(power/500)
300
1300
Any non-ISM frequencyBelow 500
500 or more
15
15 * SQRT(power/500)
300
1300
Industrial heaters and RF stabilized arc weldersOn or below 5,725 MHz
Above 5,725 MHz
Any
Any
10
(2)
1,600
(2)
Medical diathermyAny ISM frequency
Any non-ISM frequency
Any
Any
25
15
300
300
UltrasonicBelow 490 kHzBelow 500
500 or more
2,400/F(kHz)
2,400/F(kHz) * SQRT(power/500)
300
3300
490 to 1,600 kHz
Above 1,600 kHz
Any
Any
24,000/F(kHz)
15
30
30
Induction cooking rangesBelow 90 kHz
On or above 90 kHz
Any
Any
1,500
300
430
430

1 Field strength may not exceed 10 [MICRO]V/m at 1600 meters. Consumer equipment operating below 1000 MHz is not permitted the increase in field strength otherwise permitted here for power over 500 watts.

2 Reduced to the greatest extent possible.

3 Field strength may not exceed 10 [MICRO]V/m at 1600 meters. Consumer equipment is not permitted the increase in field strength otherwise permitted here for over 500 watts.

4 Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field strength limits for miscellaneous ISM equipment.

(c) The field strength limits for RF lighting devices shall be the following:

Frequency (MHz)Field strength limit at 30 meters ([MICRO]V/m)
Non-consumer equipment:
30-8830
88-21650
216-100070
Consumer equipment:
30-8810
88-21615
216-100020

47 C.F.R. §18.305

50 FR 36070, Sept. 5, 1985, as amended at 51 FR 17970, May 16, 1986; 52 FR 43197, Nov. 10, 1987

1. The tighter limit shall apply at the boundary between two frequency ranges.

2. Testing for compliance with these limits may be made at closer distances, provided a sufficient number of measurements are taken to plot the radiation pattern, to determine the major lobes of radiation, and to determine the expected field strength level at 30, 300, or 1600 meters. Alternatively, if measurements are made at only one closer fixed distance, then the permissible field strength limits shall be adjusted using 1/d as an attenuation factor.