Table 172.065(a)-Extent of Damage
COLLISION PENETRATION | |
Longitudinal extent | 0.495L 2/3 or 47.6 feet ((1/3)L 2/3 or 14.5m) whichever is shorter. |
Transverse extent1 | B/5 or 37.74 feet (11.5m) which is shorter. |
Vertical extent | From the baseline upward without limit. |
GROUNDING PENETRATION AT THE FORWARD END BUT EXCLUDING ANY DAMAGE AFT OF A POINT 0.3L AFT OF THE FORWARD PERPENDICULAR | |
Longitudinal extent | 0.495L 2/3 or 47.6 feet ((1/3)L 2/3 or 14.5m) whichever is shorter. |
Transverse extent | B/6 or 32.81 feet (10m) whichever is shorter but not less than 16.41 feet (5m). |
Vertical extent from the baseline | B/15 or 19.7 feet (6m) whichever is shorter. |
GROUNDING PENETRATION AT ANY OTHER LONGITUDINAL POSITION | |
Longitudinal extent | L/10 or 16.41 feet (5m) whichever is shorter. |
Transverse extent | 16.41 feet (5m). |
Vertical extent from the baseline | B/15 or 19.7 feet (6m) whichever is shorter. |
GROUNDING PENETRATION FOR RAKING DAMAGE | |
For tank vessels of 20,000 DWT and above, the following assumed bottom raking damage must supplement the damage assumptions: | |
Longitudinal extent | For vessels of 75,000 DWT and above, 0.6L measured from the forward perpendicular. |
For vessels of less than 75,000 DWT, 0.4L measured from the forward perpendicular. | |
Transverse extent | B/3 anywhere in the bottom. |
Vertical extent | Breach of the outer hull. |
1 Damage applied inboard from the vessel's side at right angles to the centerline at the level of the summer load line assigned under Subchapter E of this chapter.
Table 172.065(b)-Permeability
Spaces and tanks | Permeability (percent) |
Storeroom spaces | 60. |
Accommodation spaces | 95. |
Voids | 95. |
Consumable liquid tanks | 95 or 0.1 |
Other liquid tanks | 95 or 0.2 |
1 Whichever results in the more disabling condition.
2 If tanks are partially filled, the permeability must be determined from the actual density and amount of liquid carried.