46 C.F.R. § 162.050-19

Current through September 30, 2024
Section 162.050-19 - Oil content meter and bilge alarm test rig
(a) This section contains requirements for test rigs used in approval testing of oil content meters and meter. A typical test rig is described in Figure 162.050-19. The mixture pipe shown in Figure 162.050-19 is the portion of test rig piping between the oil injection point and the meter or bilge alarm piping.
(b) Each sample point on a test rig must be of the type described in Figure 162.050-17(e) and must be in a vertical portion of the test rig piping.
(c) Each test rig must have a centrifugal pump that is designed to operate at 1,000 revolutions per minute or more.
(d) The mixture pipe on a test rig must have a uniform inside diameter.

FIGURE 162.050-19-MONITOR AND BILGE ALARM TEST RIG

View Image

46 C.F.R. §162.050-19

CGD 76-088a, 44 FR 53359, Sept. 13, 1979, as amended by USCG-2004-18939, 74 FR 3385, Jan. 16, 2009