46 C.F.R. § 154.544

Current through November 30, 2024
Section 154.544 - Quick-closing shut-off valves

The quick-closing shut-off valve under §§ 154.530 , 154.532 and 154.538 must:

(a) Be a shut-off valve;
(b) Close from the time of actuation in 30 seconds or less;
(c) Be the fail-closed type; and
(d) Be capable of local manual closing.

46 C.F.R. §154.544