46 C.F.R. § 154.530

Current through November 30, 2024
Section 154.530 - Valves: Cargo tank MARVS 69 kPa gauge (10 psig) or lower
(a) Except those connections for tank safety relief valves and for liquid level gauging devices other than those under §§ 154.536 and 154.1310 , liquid and vapor connections on a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have shut-off valves that-
(1) Are located as close to the tank as practical;
(2) Are capable of local manual operation; and
(3) May be remotely controlled.
(b) The cargo piping system for a cargo tank with a MARVS of 69 kPa gauge (10 psig) or lower must have at least one remotely controlled quick-closing shut-off valve for closing liquid and vapor piping between vessel and shore that meets §§ 154.540 and 154.544 .

46 C.F.R. §154.530

CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 77-069, 52 FR 31630, Aug. 21, 1987