46 C.F.R. § 151.50-36

Current through November 30, 2024
Section 151.50-36 - Argon or nitrogen
(a) A cargo tank that contains argon or nitrogen and that has a maximum allowable working pressure of 172 kPa (25 psig) or greater must have one of the following arrangements:
(1) A refrigeration system that keeps the tank pressure below the safety relief valve operating pressure when ambient temperatures are 46 °C (115 °F) air and 32 °C (90 °F) water.
(2) A relief valve or pressure control valve that maintains the tank pressure below the setting of the tank's required safety relief valve in ambient temperatures of 46 °C (115 °F) air and 32 °C (90 °F) water.
(b) A cargo tank with a maximum allowable working pressure of less than 172 kPa (25 psig) is approved by the Commandant (CG-ENG) on a case by case basis.
(c) Section 151.50-30 also applies to the carriage of argon or nitrogen.

46 C.F.R. §151.50-36

CGD 88-100, 54 FR 40040, Sept. 29, 1989