Current through September 30, 2024
Section 116.405 - [Effective 10/18/2024] General arrangement and outfitting(a)Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable.(b)Combustible materials to be limited. Limited amounts of combustible materials such as wiring insulation, pipe hanger linings, nonmetallic (plastic) pipe, and cable ties are permitted in concealed spaces except as otherwise prohibited by this subpart.(c)Combustibles insulated from heated surfaces. Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material.(d)Separation of machinery and fuel tank spaces from accommodation spaces. Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors.(e)Paint and flammable liquid lockers. Paint and flammable liquid lockers must be constructed of steel or equivalent material, or wholly lined with steel or equivalent material.(f)Nonmetallic piping in concealed spaces. The use of nonmetallic (plastic) pipe within a concealed space in a control space, accommodation space, or service space is permitted in nonvital service only if the piping material has been approved under § 164.141 of this chapter and meets both low flame spread rating and toxicity requirements.(g)Vapor barriers. Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers.(h)Interior finishes. Combustible interior finishes allowed by § 116.422(d) of this part must not extend into hidden spaces, such as behind linings, above ceilings, or between bulkheads.(i)Waste Receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.(j)Mattresses. All mattresses must comply with either: (1) The U.S. Department of Commerce Standard for Mattress Flammability (FF 4-72.16), 16 CFR Part 1632, Subpart A and not contain polyurethane foam; or,(2) International Maritime Organization Resolution A.688(17) "Fire Test Procedures For Ignitability of Bedding Components." Mattresses that are tested to this standard may contain polyurethane foam.CGD 85-080, 61 FR 900, Jan. 10, 1996, as amended at 62 FR 51348, Sept. 30, 1997; USCG-2000-7790, 65 FR 58462, Sept. 29, 2000