46 C.F.R. § 111.75-17

Current through November 30, 2024
Section 111.75-17 - Navigation lights

Each navigation light system must meet the following:

(a)Feeders. On vessels required to have a final emergency power source by § 112.05-5(a) of this chapter, each navigation light panel must be supplied by a feeder from the emergency switchboard (see § 112.43-13 ). The feeder must be protected by overcurrent devices rated or set at a value of at least twice that of the navigation light panel main fuses.
(b)Navigation light indicator panel. Each self-propelled vessel must have a navigation light indicator panel in the navigating bridge to control side, masthead, and stern lights. The panel must visually and audibly signal the failure of each of these navigation lights. Each light source must be connected to a separate fused branch circuit. The panel must have a fused feeder disconnect switch, and the fuses must have at least twice the rating of the largest branch circuit fuse and must be greater than the maximum panel load.
(c)Dual light sources. Each self-propelled vessel must have duplicate light sources for the side, masthead, and stern lights.
(d)Navigation lights. Each navigation light must meet the following:
(1) Meet the technical details of the applicable navigation rules.
(2) Be certified by an independent laboratory to the requirements of ANSI/UL 1104 or EN 14744 (incorporated by reference; see § 110.10-1 of this subchapter) or an equivalent standard under § 110.20-1 of this subchapter. Portable battery powered navigation lights need only be certified to the requirements of ANSI/UL 1104 applicable to those lights.
(3) Be labeled with a label stating the following:
(i) "MEETS __________." (Insert the identification name or number of the standard under paragraph (d)(2) of this section to which the light was type-tested.)
(ii) "TESTED BY __________." (Insert the name or registered certification mark of the independent laboratory that tested the fixture to the standard under paragraph (d)(2) of this section).
(iii) Manufacturer's name.
(iv) Model number.
(v) Visibility of the light in nautical miles.
(vi) Date on which the fixture was type-tested.
(vii) Identification of bulb used in the compliance test.
(4) If it is a flashing light, have its intensity determined by the formula:

Ie = G/(0.2 + t2-t1)

Where

Ie = Luminous Intensity.

G = Integral of Idt evaluated between the limits of t1 and t2.

t1 = Time in seconds of the beginning of the flash.

t2 = Time in seconds of the end of the flash.

I = Instantaneous intensity during the flash.

46 C.F.R. §111.75-17

CGD 74-125A, 47 FR 15236, Apr. 8, 1982, as amended by CGD 94-108, 61 FR 28282, June 4, 1996; 61 FR 33045, June 26, 1996; 62 FR 23909, May 1, 1997; USCG-2003-16630, 73 FR 65199 , Oct. 31, 2008
88 FR 16365 , 4/17/2023

The limits, t1 and t2, are to be chosen so as to maximize Ie.