46 C.F.R. §§ 56.30-20

Current through November 30, 2024
Section 56.30-20 - Threaded joints
(a) Threaded joints may be used within the limitations specified in subpart 56.15 of this chapter and within other limitations specified in this section.
(b) (Modifies 114.1.) All threads on piping components must be taper pipe threads in accordance with the applicable standard listed in table 2 to § 56.60-1 . Threads other than taper pipe threads may be used for piping components where tightness of the joint depends on a seal weld or a seating surface other than the threads, and where experience or test has demonstrated that such threads are suitable.
(c) Threaded joints may not be used where severe erosion, crevice corrosion, shock, or vibration is expected to occur; or at temperatures over 925 °F. Size limitations are given in table 1 to § 56.30-20(c) .

Table 1 to § 56.30-20(c) -Threaded Joints 12

Maximum nominal size, inchesMaximum pressure, psig
Above 2'(Not permitted in Class I piping service.)
Above 1' up to 2'600.
Above 3/4 ' up to 1'1,200.
3/4 ' and below1,500.

1 Further restrictions on the use of threaded joints appear in the low temperature piping section.

2 Threaded joints in hydraulic systems are permitted above the pressures indicated for the nominal sizes shown.

(d) No pipe with a wall thickness less than that of standard weight of ASME B36.10M (incorporated by reference; see § 56.01-2 ) steel pipe may be threaded. For restrictions on the use of pipe in steam service more than 250 psig or water service over 100 psig and 200 °F (93.3 °C), see part 104.1.2(c)(1) of ASME B31.1 (incorporated by reference; see § 56.01-2 ).

46 C.F.R. §§56.30-20

CGFR 68-82, 33 FR 18843, Dec. 18, 1968, as amended by CGFR 69-127, 35 FR 9978, June 17, 1970; CGD 73-254, 40 FR 40164, Sept. 2, 1975; CGD 77-140, 54 FR 40606, Oct. 2, 1989; USCG-2003-16630, 73 FR 65178 , Oct. 31, 2008
89 FR 50131 , 9/10/2024