FORMULA 1 TO § 54.15-15(C)(1)
W = 51.45AP
FORMULA 2 TO § 54.15-15(C)(2)
W = 105.3A[RADIC] P1 (P-P1)
where:
W = The required orifice capacity, in pounds per hour.
A = Cross-sectional area of rounded entrance orifice, in square inches. The orifice must be installed near the steam inlet or the coils or tubes and where no orifice is employed the area used in the formula must be that of the inlet connection or manifold.
P = Set pressure of steam supply safety valve, in pounds per square inch, absolute.
P1 = Set pressure of evaporator shell safety valve, in pounds per square inch, absolute.
FORMULA 3 TO § 54.15-15(G)(2)
Q = 29.81KD 2[RADIC] P1 -P2
where:
Q = Required relief valve discharge capacity, in gallons per minute, based on relief valve set pressure.
P1 = Pressure in the tube or coils, in pounds per square inch.
P2 = Set pressure of the shell relief valve, in pounds per square inch.
D = Internal diameter of the largest tube or coil, in inches.
K = Coefficient of discharge = 0.62.
46 C.F.R. §§54.15-15