Table 28.140-Scheduled Maintenance and Inspection of Lifesaving Equipment
Item | Interval | Regulation | |
Monthly | Annually | ||
(1) Inflatable wearable personal flotation device (Type V commercial hybrid) | Servicing | 28.140 | |
(2) Personal flotation devices, exposure suits and immersion suits | Inspect, clean and repair as necessary | 28.140 | |
(3) Buoyant apparatus and life floats | Inspect, clean and repair as necessary | 28.140 | |
(4) Inflatable liferaft | Servicing1 | 28.140 | |
(5) Inflatable buoyant apparatus | Servicing1 | 28.140 | |
(6) Hydrostatic release | Servicing1 | 28.140 | |
(7) Disposable hydrostatic release | Replace on or before expiration date | 28.140 | |
(8) Undated batteries | Replace | 28.140 | |
(9) Dated batteries2 and other items | Replace on or before expiration date | 25.26-50, 28.140 | |
(10) EPIRB | Test | 25.26-50 |
1 For a new liferaft or inflatable buoyant apparatus, the first annual servicing may be deferred to two years from the date of first packing if so indicated on the servicing sticker.
2 Water activated batteries must be replaced whenever they are used.
46 C.F.R. §28.140