Current through September 30, 2024
Section 3175.114 - Spot samples-allowable methods(a) Spot samples must be obtained using one of the following methods: (1)Purging-fill and empty method. Samples taken using this method must comply with GPA 2166-05, Section 9.1 (incorporated by reference, see § 3175.30 );(2)Helium "pop" method. Samples taken using this method must comply with GPA 2166-05, Section 9.5 (incorporated by reference, see § 3175.30 ). The operator must maintain documentation demonstrating that the cylinder was evacuated and pre-charged before sampling and make the documentation available to the AO upon request;(3)Floating piston cylinder method. Samples taken using this method must comply with GPA 2166-05, Sections 9.7.1 to 9.7.3 (incorporated by reference, see § 3175.30 ). The operator must maintain documentation of the seal material and type of lubricant used and make the documentation available to the AO upon request;(4)Portable gas chromatograph. Samples taken using this method must comply with § 3175.118 ; or(5) Other methods approved by the BLM (through the PMT) and posted at www.blm.gov.(b) If the operator uses either a purging-fill and empty method or a helium "pop" method, and if the flowing pressure at the sample port is less than or equal to 15 psig, the operator may also employ a vacuum-gathering system. Samples taken using a vacuum-gathering system must comply with API 14.1, Subsection 11.10 (incorporated by reference, see § 3175.30 ), and the samples must be obtained from the discharge of the vacuum pump.