40 C.F.R. § 1065.715

Current through September 30, 2024
Section 1065.715 - Natural gas
(a) Except as specified in paragraph (b) of this section, natural gas for testing must meet the specifications in the following table:

TABLE 1 OF § 1065.715 -TEST FUEL SPECIFICATIONS FOR NATURAL GAS

Property Valuea
Methane, CH4Minimum, 0.87 mol/mol.
Ethane, C2 H6Maximum, 0.055 mol/mol.
Propane, C3 H8Maximum, 0.012 mol/mol.
Butane, C4 H10Maximum, 0.0035 mol/mol.
Pentane, C5 H12Maximum, 0.0013 mol/mol.
C6 and higherMaximum, 0.001 mol/mol.
OxygenMaximum, 0.001 mol/mol.
Inert gases (sum of CO2 and N2)Maximum, 0.051 mol/mol.

a Demonstrate compliance with fuel specifications based on the reference procedures in ASTM D1945 (incorporated by reference, see § 1065.1010 ), or on other measurement procedures using good engineering judgment.

(b) In certain cases you may use test fuel not meeting the specifications in paragraph (a) of this section, as follows:
(1) You may use fuel that your in-use engines normally use, such as pipeline natural gas.
(2) You may use fuel meeting alternate specifications if the standard-setting part allows it.
(3) You may ask for approval to use fuel that does not meet the specifications in paragraph (a) of this section, but only if using the fuel would not adversely affect your ability to demonstrate compliance with the applicable standards in this chapter.
(c) When we conduct testing using natural gas, we will use fuel that meets the specifications in paragraph (a) of this section.
(d) At ambient conditions, natural gas must have a distinctive odor detectable down to a concentration in air not more than one-fifth the lower flammable limit.

40 C.F.R. §1065.715

73 FR 37342, June 30, 2008, as amended at 79 FR 23811, Apr. 28, 2014; 86 FR 34573, June 29, 2021; 88 FR 4687, Jan. 24, 2023; 89 FR 29823, Apr. 22, 2024
86 FR 34573, 7/29/2021; 88 FR 4687, 3/27/2023; 89 FR 29823, 6/21/2024